Adult
| Apex™ |
 |
Apex™ Oxygenator:
- Advance flow design provides improved oxygen transfer
- Integral purge and recirculation line simplifies priming and tubing pack design
- Unique cardioplegia port provides access to arterial blood without cutting into tubing
- Highest gas transfer available from COBE CV
- Venous inlet, lid, reservoir and oxygenator rotate independently
- Same temperature probe and bracket as Optima XP and Duo
HVR/VVR4000i:
- Computational fluid modeling for enhanced flow dynamics
- Excellent low volume resolution
- Horizontal outlet minimizes vortexing
- Integral SAT/HCT Connection
- Rotating lid, venous inlet, and reservoir for optimum port orientation
- Collective grouping of ports simplifies lid design reduces clutter
- VVR has a sealed lid and is indicated for vacuum assisted drainage
|
| Optima XP™ |
 |
Optima XP™ with HVR™/VVR™4000i
Advanced flow dynamics and increased oxygen transfer
Optima XP™:
- High gas transfer reserve capacity for extra oxygenation when you need it
- Efficient hollow fiber, cross wound mat technology for consistent performance
- Top to bottom membrane flow for enhanced air handling
- Bottom to top heat exchanger flow for ease of priming
- High performance/high integrity heat exchanger
- Ultra-low priming volume
HVR/VVR4000i:
- Computational fluid modeling for enhanced flow dynamics
- Excellent low volume resolution
- Horizontal outlet minimizes vortexing
- Integral SAT/HCT Connection
- Rotating lid, venous inlet, and reservoir for optimum port orientation
- Collective grouping of ports simplifies lid design reduces clutter
- VVR has a sealed lid and is indicated for vacuum assisted drainage
|
| Duo® |
 |
CML DUO® with HVR/VVR4000i
Advanced flow dynamics and exclusive flat sheet technology
CML DUO®:
- Flat sheet membrane for enhanced air handling
- Continuous bloodside netting improves gas exchange
- Top to bottom membrane flow for enhanced air handling
- Bottom to top heat exchanger flow for ease of priming
- High performance/high integrity heat exchanger
HVR/VVR4000i:
- Computational fluid modeling for enhanced flow dynamics
- Excellent low volume resolution
- Horizontal outlet minimizes vortexing
- Integral SAT/HCT Connection
- Rotating lid, venous inlet, and reservoir for optimum port orientation
- Collective grouping of ports simplifies lid design, reduces clutter
- VVR has a sealed lid and is indicated for vacuum assisted drainage
|
| Avant |
 |
TECHNICAL FEATURES:
|
Neonatal/Pediatric
| Lilliput I |
 |
TECHNICAL FEATURES:
- Total Reservoir Capacity: 675 ml
- Venous Reservoir Capacity: 425 ml
- Cardiotomy Reservoir Capacity: 250 ml
- Minimum Operating Level: 15 ml
- Max Blood Flow: 0.8 l/min
- Ref. Blood Flow: (A.A.M.I. Standard) 1.2 l/min
- Static Priming Volume: 60 ml
- Membrane Surface Area: 0.34 sq.m.
- H.E. Performance Factor: Eta 0.71 (0.8 lt/min)
- Cardiotomy Filter Pore Size: 30 µm
|
| Lilliput II |
 |
DATA:
- Priming Volume: 105 ml
- Surface Area: 0.6 sq.m
- Softshell Ven. Res. Capacity: 190 ml
- Hardshell Ven. Res. Capacity: 1800 mls
- Max. Blood Flow: 2300 mls/min
- Ref. Flow: (A.A.M.I. Standard) 3300 mls/min
CONNECTIONS:
- Softshell Ven. Inlet: 1/4" or 3/8"
- Softshell Cardiotomy Return: according to the ven. inlet
- Softshell Ven. Outlet: 1/4"
- Hardshell Ven. Inlet: 3/8" (1/4" adapter provider)
- Hardshell Ven. Outlet: 1/4"
- Oxy. Art. Inlet: 1/4" and 5/16"
- Oxy. Art. Outlet: 1/4" and 5/16"
|
| Optimin |
 |
TECHNICAL FEATURES
- 5 Liter blood flow capability with 170ml oxygenator prime
- Efficient hollow fiber, cross wound mat technology for consistent performance
- Top to bottom membrane flow for enhanced air handling
- High performance/high integrity heat exchanger
- Rotating lid, rotating venous inlet for optimum port orientation
- Horizontal reservoir outlet minimizes vortexing
|
Caution: Federal Law (USA) restricts these devices to sale by or on the order of a physician.
Please read Instructions For Use prior to clinical applications. To aid in the prevention of gas or particulate embolization, COBE Cardiovascular recommends the use of safety devices, including level sensors, bubble detectors, arterial
filters, and prebypass filters, for all cardiopulmonary bypass procedures.
|